Description
The Relative Humidity Sensor can be used for weather studies, monitoring greenhouses, or determining days when static electrical discharges could be a problem.
ORDER CODE: RH-BTA
Specifications (Source: Vernier.com)
- Range: 0% to 95%
- Power: 200 µA @ 5 VDC
- Response Time (time for a 90% change in reading):
- In still air: 60 minutes (typical)
- With vigorous air movement: 40 seconds (typical)
- Typical Resolution: 0.04% RH
Humidity Sensor Specifications
Specifications for the IH-3602-L Integrated Circuit Humidity Sensor (at 25°C and 5.0 VDC) are given below:
- Total Accuracy (with saturated salt calibration): ±2% RH
- Total Accuracy (with standard calibration): ±10% RH
- Operating Temperature Range: 0 to 85°C
- Temperature Effect
- 0% RH voltage: ±0.007% RH/°C (negligible)
- 50% RH voltage: –0.11% RH/°C
- 95% RH voltage: –0.22% RH/°C